ASTM 119-00a (Small Scale)
Parameters: Evaluate the duration for which the types of assemblies (tested) will contain a fire, or retain their structural integrity Observations: A range of 8 different size beams was tested with varying coating thicknesses. Fire resistance ranged from 103 to 121 minutes.