Test: ASTM-84-05 (Class "A" Rating Building Materials)
Equivalent tests: (UL-723, ANSI No. 2.5, NFPA No. 255; and UBC 8-1 42-1)
Testing Agent: Intertek
Date: 3/02/06
Substrate: Douglas Fir
Method: Standard test method for surface burning characteristics of building materials.
Parameters: Flame spread Index 10; Smoke developed Index 5.

Observations: Char formed at :22 (min:sec). Ignition at :56 (min:sec) The intumescent coating began to crack at 2:15 (min:sec). Substrate ignited at 7:57 (min:sec).

Rating: The National Fire Protection Association Life Safety Code 101, Section 6-5.3, "Interior Wall and Ceiling Finish Classification"

Class "A" Rating